当前位置:网站首页>E+h secondary meter repair pH transmitter secondary display repair cpm253-mr0005
E+h secondary meter repair pH transmitter secondary display repair cpm253-mr0005
2022-06-27 08:48:00 【A Tiandao rewards the diligent ~ Tianpu Zhengda maintenance Cao】
PH Transmitter CPM253-MR0005 Germany E+H It's a standard pH/ORP Transmitter , For analog and digital Memosens Of sensor . With continuous rationality 、 Measurement process and sensor detection , Increase operability . No matter how you choose from a large number of hardware and software modules , For example, relay and bus communication , It can adapt to measurement tasks . It also allows the transmitter to be upgraded at any time , Its simple menu and factory calibration make the configuration and operation convenient and fast .
PH Transmitter CPM253-MR0005 Germany E+H advantage :
Higher operability : Continuous process inspection system , Custom alarm settings , Optimization of the Memosens The interface can realize the sensor connection .
Self monitoring : The sensor inspection system is used for pH calibration , Calibration authenticity check .
Easy to operate and maintain : Intuitive user interface , Pre calibration Memosens The sensor supports hot plugging , Direct manual contact control .
Reduce maintenance effort : Start the automatic cleaning function through the alarm or limit switch ( Use Chemoclean).
The main reasons for the stagnation of measured values are as follows :
The sensor is contaminated , Or the sensor is not immersed in the medium
Sensor fault
Process error ( for example : Through the control system )
Rationality check :
Usually , With the same pH Value calibration . therefore , When performing the next calibration , The transmitter regards the setting value of the last calibration as the default value . When the calibration fluid is changed by mistake during calibration ( for example : First use pH 4 Calibration solution for , Subsequent use pH 7 Calibration solution for ; Instead of using pH 7 Calibration solution for , Subsequent use pH 4 Calibration solution for ), The rationality check ensures that the calibration results are reasonable .
Current output setting : Large output range , And still need to ensure high-resolution output within the range , You can set the current output through the table . You can use bilinear and square root curves .
The current input of the transmitter has the following two functions :
When the main flow is lower than the lower limit of flow , Turn off the controller flow monitoring function
The two functions of controller feedforward control can be used at the same time .
Neutralization reaction controller : Solution neutralization reactions require a controlled response , A single P(ID) The response cannot satisfy . The transmitter will have two P(ID) The controller is used as the neutralization reaction controller .
Process control precautions :
Different alarms are required for applications and operators . therefore , The transmitter can be configured for each erroneously set transmitter fault signal contact and error current . This method can suppress unwanted or unexpected alarm signals . Four contact switches can be set , Used as limit contact ( The same applies to temperature )、P(ID) controller 、 Or cleaning function . Direct manual contact setting ( Through menu settings ), The limit value can be viewed quickly 、 Control contact and cleaning contact . The deviation can be corrected quickly .
边栏推荐
猜你喜欢
That is, a one-stop live broadcast service with "smooth live broadcast" and full link upgrade
并发编程JUC的AQS底层源码
June 26, 2022 (LC 6100 counts the number of ways to place houses)
提高效率 Or 增加成本,开发人员应如何理解结对编程?
一种太阳能电荷泵供电电路的方案设计
Getting started with webrtc: 12 Rtendpoint and webrtcendpoint under kurento
C # solve the relative path problem using SQLite
IO pin configuration and pinctrl drive
Matlab tips (19) matrix analysis -- principal component analysis
即构「畅直播」,全链路升级的一站式直播服务
随机推荐
AQS underlying source code of concurrent programming JUC
Lvgl usage demo and instructions 2
关于放大器失真的原因你了解多少呢?
Getting started with webrtc: 12 Rtendpoint and webrtcendpoint under kurento
Design of a solar charge pump power supply circuit
CLassLoader
IO管脚配置和pinctrl驱动
Internal class ~ lock ~ access modifier
JVM层次上的对象的创建过程和内存布局
That is, a one-stop live broadcast service with "smooth live broadcast" and full link upgrade
Analysis log log
Chapter 11 signal (I) - concept
Rough reading DS transunet: dual swing transformer u-net for medical image segmentation
Brief introduction to SSL encryption process
The most direct manifestation of memory leak
oracle怎样将字符串转为多行
ServletConfig与ServletContext
Enumeration? Constructor? Interview demo
Redis配置文件详解
MATLAB小技巧(19)矩阵分析--主成分分析